Basic Introduction
DSCD-910 Transmitted liquid Desktop Spectrophotometer is good performance and specially designed for testing the liquid transmittance, absorbance, concentration, chrominance and other parameters. The instrument adopts the measurement structure of D/0, integration of the full band LED composite light source, double beam optical system, ETC every-time calibration technology, which makes the instrument reaches a resolution of 0.0001, deviation of the transmittance within 0.08% and chromatic value: △E*ab 0.015.
Brief Introduction
• D\0 Structure
• It is suitable for testing the glass and liquid color
• Adopt UV enhanced silicon photodiode
Expend the transmittance from 0~100% to 0~200%.
• Pt-Co and Gardner Index- Liquid Yellow Degree Characteristics
The unit of Pt-Co is suitable for testing transparent liquid or brown liquid whose color similar to one unit Pt-Co calm chroma.
Gardner Color Code is suitable for the liquid whose color is darker than Pt-Co color.
• Matching color analysis software
Technical Data
Type | DSCD-910 |
Illumination | d/0 (Diffused illumination, 0°viewing) SCS optical engine (light splitting and integration system), (conform to CIE No.15, ISO 7724/1, ASTM E1164, DIN 5033 Teil7, JIS Z8722 Condition standards) |
Size of integrating sphere | Φ40mm, Alvan diffused reflection surface coating |
Illumination Light source | CLEDs (entire wavelength balanced LED light source) |
Sensor | dual light path sensor array |
Wavelength range | 400-700nm |
Wavelength interval | 10nm |
Half spectral width | 5nm |
Reflectivity range | 0-200% |
Reflectivity resolution | 0.01% |
Observation angle | 2°/10° |
Measurement light source | A, C, D50, D55, D65, D75, F1, F2, F3, F4, F5, F6, F7, F8, F9, F10, F11, F12, CWF, U30, DLF, NBF, TL83, TL84 |
Data being displayed | Transmittance graph/value, chromatic value, color difference values, color assessment results, color tendency, history color value simulation, manual input standard sample, generate measurement reports |
Measurement time interval | 2 seconds |
Measurement time | 0.5 seconds |
Color space | CIE-L*a*b, L*C*h, CIE-L*u*v, XYZ, Yxy, Transmittance, Hunterlab, Munsell MI, CMYK |
Color difference formulas | ΔE*ab, ΔE*CH, ΔE*uv, ΔE*cmc (2:1), ΔE*cmc (1:1), ΔE*94, ΔE*00, ΔEab (Hunter), color classification |
Other colorimetric indices | WI (ASTM E313-10, ASTM E313-73, CIE/ISO, AATCC, Hunter, Taube Berger, Ganz, Stensby), YI (ASTM D1925, ASTM E313-00, ASTM E313-73), Tint (ASTM E313-00, CIE, Ganz), Metamerism index Milm, Stick color fastness, Color fastness, APHA, Pt-Co, Gardner |
Repeatability | light splitting reflectivity: standard deviation within 0.08% |
color values: ΔE*ab <=0.015 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals, Maximum: 0.03) | |
Interface | USB |
Data storage | mass storage |
Light source longevity | 5 years, 1.5 million tests |
Size | 475*340*150mm (L*W*H) |
Weight | about 7kg |
Work temperature range | 0~45℃, relative humidity 80% or below (at 35°C), no condensation |
Storage temperature range | 25℃ to 55℃, relative humidity 80% or below (at 35°C), no condensation |
Standard accessories | AC power line, color management software, drive software, USB cable, black calibration tube, 40*10mm cuvette |